Home/Products/Oil Sheen Sensors/ID-223/500 Oil Sheen Sensor
Oil Sheen Sensors

ID-223/500 Oil Sheen Sensor

ID-223/500 Oil Sheen Sensor

Applications

LEAKWISE ID-223/500 sensors excel in detecting thin layers of hydrocarbons on water surfaces in various environments prone to oil leaks, including both wet and dry sumps. These advanced sensors not only detect the presence of oil but also monitor its accumulation, providing valuable oil layer thickness trend data.

The ID-223/500 is particularly effective in early spill detection and monitoring in:

  • Above-ground oil storage tanks
  • Transformer sumps in switchyards and remote power distribution substations
  • Oil/water separators
  • Cooling water systems and trenches
  • Stormwater runoff collection ponds
  • Wastewater sewer networks.

The sensor’s versatility extends to detecting and monitoring hydrocarbon leaks and spills in sumps, canals, and retention ponds. Furthermore, the ID-223/500 plays a crucial role in monitoring oil/water separators and wastewater treatment plant discharge, ensuring regulatory compliance and alerting plant operators to any disruptions in the treatment process.

ID-223/500 Description

A LEAKWISE system comprises a controller and one or more sensors. The ID-223/500 sensor features a high-frequency transmitter mounted on a float, built within a guiding cage. This design allows the sensor to maintain precise positioning at the liquid/air interface, even with liquid level fluctuations up to 500 mm (19.7 in).

Each ID-223/500 sensor operates in conjunction with the analog PS-220 Controller, which offers two field-adjustable alarm points:

  • Low oil alarm – Triggers upon detection of an initial predefined hydrocarbon layer thickness
  • High oil alarm – Activates when the hydrocarbon layer reaches a second predefined thickness or detects a dry sump situation in certain applications

The ID-223/500 boasts exceptional sensitivity, capable of reliably detecting oil layers as thin as 0.3 mm (0.01 in) without false alarms. It continuously monitors changes in oil layer thickness up to 20 mm (0.8 in), transmitting this data via a 4-20 mA output signal from the controller. The system utilizes controller relays for both local and remote alarm and control functions. Built-in diagnostics continuously monitor sensor operation, ensuring reliable performance.

For more complex installations, the SLC-220 digital controller can manage up to four sensors simultaneously. To optimize performance in areas with high water flow or turbulence, a stilling tube is recommended for ID-223/500 installations where lateral water velocity exceeds 30 cm/sec (11.8 in/sec). An integral guiding cage stiller is available as an optional accessory.

The LEAKWISE ID-223/500 is specifically designed for environments with maximum water fluctuations of up to 500 mm (19.7 in), making it ideal for applications where moderate water level changes are expected. In cases where abnormal water levels can happen during emergencies, an anti-submersion air pocket cap accessory can be added to the guiding cage.

Principle of Operation

LEAKWISE ID-220 series sensors employ advanced high-frequency Electromagnetic Absorption technique. Each floating sensor contains high-frequency electromagnetic energy transmitting and receiving antennas that provide continuous monitoring of the liquid surface. This technology exploits the principle that water absorbs more electromagnetic energy than hydrocarbons. Consequently, changes in the water’s absorption rate at the top layer indicate the presence or accumulation of hydrocarbons.

LEAKWISE sensors are engineered to detect and monitor the buildup of both separated and emulsified non-soluble hydrocarbons on water and other aqueous solutions. A unique feature of these sensors is their ability to differentiate between wet and dry sump conditions, a capability unmatched by other oil sheen monitoring systems, allowing the indication of water level below the minimum required.

Download PDF

ID-223/500 Oil Sheen Sensor Specifications:

The ID-223/500 Oil Sheen Sensor is a versatile and highly sensitive device designed for detecting and monitoring separated hydrocarbon layers on water surfaces, including in sumps that may be dry. This floating sensor is capable of detecting oil layers as thin as 0.3 mm and monitor oil thickness up to 20 mm. It operates effectively within a water level variation range of 40 – 500 mm (1.6 – 19.7 in), adapting to moderate level fluctuations.

Key features include:

  • Detection range: 0.3 – 20 mm of hydrocarbon on water or brine (settable in the controller)
  • Water level variation range: 40 mm up to 500 mm (19.7 in)
  • Operating temperature: 0 – 70°C for water, -10 – 80°C for air
  • Water lateral velocity tolerance: Up to 30 cm/sec without a stiller; can be doubled with a stiller
  • Intrinsically safe design for hazardous areas
  • Integral cable length of 10 m, extendable as needed
  • Compatible with PS-220 analog controller and SLC-220 digital controller
  • Optional 4-20 mA output for oil thickness monitoring
  • Dual alarm system for low and high oil detection

The ID-223/500 is constructed with a 160 mm (6.3 in) diameter sensor made of hydrocarbon-resistant polymers and 316 stainless steel, ensuring durability in harsh environments. Its guiding cage has a diameter of 180 mm (7.1 in), allowing for stable operation. This robust design, coupled with continuous self-diagnostics, makes it a reliable solution for long-term hydrocarbon monitoring in various industrial applications, particularly where moderate water level changes are expected.

Operating Range:

Detection Range0.3 – 20 mm (0.01 – 0.8 in) of separated hydrocarbon on water or brine
Water Level Variation40 mm (1.6 in) up to 500 mm (19.7 in), above bottom flange
Water Lateral Velocity~30 cm/sec (~11.8 in/sec) without a stiller; May be doubled with a stiller
Water Temperature0 – 70 °C (32 – 158 °F); no freezing
Air Temperature-10 – 80 °C (14 – 176 °F)

Physical Specifications:

MaterialsHydrocarbon resistant polymers (Polypropylene, PVC, Polyurethane), 316 stainless steel.
Diameter160 mm (6.3 in).
Integral Cable10 m (~33 ft.) supplied with sensor, 3 x 18 AWG, blue PVC jacket.
Guiding Cage Dia.180 mm (7.1 in)

Accessories:

  • Integral cage stiller
  • Anti-Submersion air pocket cap

Sensor and PS-220 Controller Certifications

ID-223 Sensor : ATEX Intrinsically Safe: II1G Ex ia IIC T4 Ga -40 °C to +70 °C. Also: IECEx, UKEX and cETLus

PS-220 Enclosure For hazardous areas:

  • North America – NEMA 7, Class I, Div 1, Groups B, C & D; NEMA 4
  • Europe ATEX & IECEx – II2(1)GD, Ex db [ia Ga] IIC T6 Gb IP66
Combined SystemApproved for operation in hazardous locations when Zener Safety Barriers are added
PerformanceEPA – Conforms to Spill Prevention, Control and Countermeasure (SPCC) – Oil Pollution Prevention regulation (40 CFR part 112), and EPA/530/UST-90/009 – Leak Detection Methods
ManufacturingISO 9001:2015 Certified

PS-220 Controller

PS-220 DescriptionPS-220 Controller is an analog signal processor and power supply in a NEMA 4 enclosure that supports a single ID-223 sensor.
TemperatureAmbient temperature range: -40 – 85 °C (-40 – 185 °F)
Cable length to SensorUp to 1,200 m (3,937 ft.) subject to hazardous area restrictions and cable type.
PS-220/RL/LITwo alarm relays with dry contacts and one fail relay contact; SPDT rated 4A (3A for fail contact) at 250 VAC or 30 VDC, normally open and normally closed, and four status indication lights: Water, Oil, Air/High Oil and Fail. Includes built-in diagnostics.
Wiring ConnectionsTerminal blocks: 14 AWG maximum for sensor and 4-20 mA output wires; 12 AWG maximum for power and relays wires.

OPTIONS

Enclosure Options:

  • /N4 for NEMA 4X (IP65): 305 x 195 x 120 mm (12.0 x 7.7 x 4.7 in) 2 Kg (4.4 lb.);
  • /N7 for NEMA 7: 278 x 259 x 166 mm (11.0 x 10.2 x 6.5 in) 8.5 Kg (18.7 lb.);
  • /Exd for Ex d: 268 x 268 x 210 mm (10.6 x 10.6 x 8.3 in), 11.2 Kg (24.7 lb.);
  • /BP: without an enclosure, to be mounted in a local cabinet. 190 x 180 x 130 mm, 1 Kg.
Input Power Options220 or 110 VAC (50 – 60 Hz) or 9 – 36 VDC (@ 5 Watts); may also be solar powered.
/4204-20 mA analog output proportional to hydrocarbon thickness up to 25 mm (1.0 in), current source, not isolated.
/420/BGBar-Graph display (20 bars) of hydrocarbon thickness in addition to 4-20 mA analog output.
/CENZener Safety Barriers to allow installation of the sensor in hazardous areas.
/AUDAudio alarm option (available in weather-proof or explosion-proof enclosure)

Other Controllers – Refer to separate data sheets

SLC-220: Digital Signal Processor for up to four ID-220 Series sensors support, with various output options, including relays, lights, 4-20 mA, LCD, Modbus communication in RS-232 and RS-485, and remote cellular connectivity.

Compare

Sensor models at a glance

Seven LEAKWISE ID-220 series sensors. Not sure which one fits? Use the Sensor Selection Tool →

Draft – compiled from the product pages and data sheets; to be checked against slide 29 of the sales-partners presentation
ModelWhat it measuresOil layer rangeWater level changeTypical useDetails
ID-221Oil sheen: detection + layer-thickness trend0.3 – 25 mm30 cm up to 45 mWet sumps, tanks, monitoring wells, oil/water separators, very deep sumps, sewersData sheet (PDF)
ID-223/500Oil sheen: detection + layer-thickness trend0.3 – 20 mm40 – 500 mmSumps (wet or dry), canals, retention ponds with small level changesData sheet (PDF)
ID-223/2000Oil sheen: detection + layer-thickness trend0.3 – 20 mm70 – 2,000 mm (up to 5,000 mm on request)Sumps (wet or dry), canals, retention ponds with large level changesData sheet (PDF)
ID-223/2500Oil sheen: detection + layer-thickness trend0.3 – 20 mm70 – 2,500 mm (up to 4,000 or 5,500 mm on request)Large level changes in small-area sumps, including dry sumpsData sheet (PDF)
ID-225/100Oil layer thickness (linear measurement)1 – 100 mm30 cm up to 45 mRemediation control, skim tanks, oil/water separators, wastewaterData sheet (PDF)
ID-225/200Oil layer thickness (linear measurement)1 – 200 mm33 cm up to 45 mRemediation control, skim tanks, oil/water separators, wastewaterData sheet (PDF)
ID-223ETEthanol concentration in water (also methanol)n/a – ethanol 10 – 100 % by volumeUp to 500 / 2,000 / 2,500 mm by sub-model (up to 5,000 / 5,500 mm on request)Ethanol storage tanks, separators and treatment plants, stormwater and wastewater at ethanol sitesData sheet (PDF)

Water level change = the range over which the floating sensor follows the surface. Minimum sump or well diameters differ by model – see the Sensor Selection Tool.

Customize your monitoring solution

Our team is at your service.

Contact us →
Chat with us on WhatsApp