LEAKWISE ID-223ET: Advanced Ethanol Concentration Sensor

Applications:

The LEAKWISE ID-223ET sensor represents a breakthrough in ethanol leak detection and concentration monitoring. As the world’s first continuous field instrument for ethanol in water technology.

The ID-223ET sensor is designed for continuous detection and measurement of ethanol in water or of Gasoline-Ethanol mixtures, specifically targeting sites where ethanol leaks or spills can occur.

This advanced sensor provides real-time monitoring of ethanol concentration, making it invaluable for the ethanol industry in leak detection and environmental protection. Key applications include:

  • Ethanol Storage Tanks: The sensor enables continuous monitoring around above-ground ethanol or gasoline-ethanol mixture storage tanks, providing early detection of leaks or spills.
  • Oil/Water Separators and Treatment Plants: In facilities handling ethanol, the ID-223ET can monitor ethanol concentrations in separators and treatment plants, ensuring effective separation and regulatory compliance and alert plant operators of any upsets in the treatment process.
  • Stormwater Run-Off Monitoring: Installed in stormwater systems at ethanol manufacturing or loading areas, the sensor detects ethanol contamination in run-off water.
  • Wastewater Sewer Systems: In ethanol manufacturing or loading areas, the ID-223ET monitors wastewater for ethanol content, helping to detect leaks at the source and prevent environmental contamination.

ID-223/ET Description:

The ID-223ET sensor is part of a LEAKWISE system, consisting of a controller and one or more sensors. This sensor features a high-frequency transmitter mounted on a float built in a guiding cage, designed to maintain precise positioning at the liquid/air interface despite fluctuations in liquid level.

Key features of the ID-223ET include:

  • Detection Range: Capable of detecting and monitoring ethanol concentrations from 10% to 100% (by volume) in water
  • Multiple Sub-models: Available in three variants to accommodate different water level fluctuations and containment size:ID-223ET/500: up to 500 mm (19.7 in) water level variationID-223ET/2000: up to 2,000 mm (6.6 ft) standard, or up to 5,000 mm (16.4 ft) on requestID-223ET/2500: up to 2,500 mm (8.2 ft) standard, or up to 5,500 mm (18 ft) on request
  • Dual Alarm System: Operates with the analog PS-220 Controller, offering two field-adjustable alarm points:Low alarm: Triggers at a first predefined low ethanol concentrationHigh alarm: Activates at a second predefined high ethanol concentration, or detects a dry sump situation
  • A 4-20 mA analog output indicating continuous ethanol concentration
  • Continuous Diagnostics: Built-in system monitors sensor operation for reliable performance
  • Compatibility: Can be integrated with the SLC-220 digital controller for managing up to four sensors
  • Accessory: A stilling tube is recommended for installations where lateral water velocity exceeds 30 cm/sec (11.8 in/sec) or where water is turbulent

The ID-223ET offers repeatable, continuous monitoring of ethanol concentration, making it an essential tool for environmental protection and regulatory compliance in various industrial applications related to ethanol production, storage, and handling. The ID-223ET is also capable of detecting ethanol in empty sumps before water fills them.

Additional Capabilities:

The ID-223ET sensor can also detect other miscible hydrocarbons in water, such as methanol, making it a versatile solution for various industrial applications.

Principle of Operation

LEAKWISE ID-220 series sensors employ advanced high-frequency Electromagnetic Absorption technique. Each floating sensor contains high-frequency electromagnetic energy transmitting and receiving antennas that provide continuous monitoring of the liquid top surface. This technology exploits the principle that water absorbs more electromagnetic energy than hydrocarbons. Consequently, changes in the water’s absorption rate at the top layer indicate the presence or accumulation of miscible hydrocarbons.

LEAKWISE sensors are engineered to detect and monitor the buildup of both separated and emulsified non-soluble hydrocarbons on water and other aqueous solutions, and the ID-223ET monitors also miscible hydrocarbons. A unique feature of these sensors is their ability to differentiate between wet and dry sump conditions, a capability unmatched by other hydrocarbon monitoring systems, allowing the indication of water level below the minimum required.

Download PDF

Ethanol in water sensor Specifications:

The ID-223ET Ethanol Concentration Sensor is a floating device designed for repeatable measurement of ethanol in water.

It offers:

  • Detection range: 10% to 100% (by volume) of ethanol in water
  • Three sub-models for different water level fluctuations (up to 5,500 mm)
  • Operating temperature: 0 – 70°C (water), -10 – 80°C (air)
  • Water lateral velocity tolerance: Up to 30 cm/sec without a stiller; can be doubled with a stiller
  • Intrinsically safe design for hazardous areas
  • Compatibility with PS-220 analog controller and SLC-220 digital controller
  • Dual alarm system for low and high ethanol concentration
  • 4-20 mA output for online indication of ethanol concentration

Constructed with durable materials, the ID-223ET is suitable for long-term monitoring in various industrial applications requiring repeatable measurement of ethanol concentrations in water.

Operating Range:

Detection Range10% to 100% (by volume) of Ethanol in water with a wide range of salinity
Water Level VariationDepends on sensor sub-model – see below
Water Lateral Velocity~30 cm/sec (~11.8 in/sec) without a stiller; May be doubled with a stiller
Water Temperature0 – 70 °C (32 – 158 °F); no freezing
Air Temperature-10 – 80 °C (14 – 176 °F)

Physical Specifications:

MaterialsHydrocarbon resistant polymers (Polypropylene, Acetal, Polyurethane), 316 stainless steel.
Diameter160 mm (6.3 in)
Integral Cable10 m (~33 ft.) supplied with sensor, 3 x 18 AWG, blue PVC jacket.

Sub-Models

ID-223ET/500 Floating Range40 – 500 mm (1.6 – 19.7 in) – Guiding Cage Dia.: 180 mm (7.1 in)
ID-223ET/2000 Floating Range70 – 2000 mm (2.8 – 78.7 in) – Guiding Cage Dia.: 560 mm (22.1 in), or up to 5,000 mm (16.4 ft) on request
ID-223ET/2500 Floating Range70 – 2500 mm (2.8 – 98.4 in) – Guiding Cage Dia.: 280 mm (11.0 in), or up to 5,500 mm (18 ft) on request

Accessories:

  • Integral stiller for all sub-models
  • Anti-Submersion air pocket for ID-223ET/500 and ID-223ET/2500

Sensor and PS-220 Controller Certifications:

ID-225/ET Sensor : ATEX Intrinsically Safe: II1G Ex ia IIC T4 Ga -40 °C to +70 °C. Also: IECEx, UKEX and cETLus

PS-220 Enclosure For hazardous areas:

North America – NEMA 7, Class I, Div 1, Groups B, C & D; NEMA 4

Europe ATEX & IECEx – II2(1)GD, Ex db [ia Ga] IIC T6 Gb IP66

Combined SystemApproved for operation in hazardous locations when Zener Safety Barriers are added
PerformanceEPA – Conforms to Spill Prevention, Control and Countermeasure (SPCC) – Oil Pollution Prevention regulation (40 CFR part 112), and EPA/530/UST-90/009 – Leak Detection Methods
ManufacturingISO 9001:2015 Certified

PS-220 Controller:

PS-220 DescriptionPS-220 Controller is an analog signal processor and power supply in a NEMA 4 enclosure that supports a single ID-223ET sensor.
TemperatureAmbient temperature range: -40 – 85 °C (-40 – 185 °F)
Cable length to SensorUp to 1,200 m (3,937 ft.) subject to hazardous area restrictions and cable type.
PS-220/RL/LITwo alarm relays with dry contacts and one fail relay contact: SPDT rated 4A (3A for fail contact) at 250 VAC or 30 VDC, normally open and normally closed, and four status indication lights: Water, Oil, Air/High Oil and Fail. Includes built-in diagnostics.
Wiring ConnectionsTerminal blocks: 14 AWG maximum for sensor and 4-20 mA output wires; 12 AWG maximum for power and relays wires.

OPTIONS:

Enclosure Options:

  • /N4 for NEMA 4X (IP65): 305 x 195 x 120 mm (12.0 x 7.7 x 4.7 in) 2 Kg (4.4 lb.);
  • /N7 for NEMA 7: 278 x 259 x 166 mm (11.0 x 10.2 x 6.5 in) 8.5 Kg (18.7 lb.);
  • /Exd for Ex d: 268 x 268 x 210mm (10.6 x 10.6 x 8.3 in), 11.2 Kg (24.7 lb.);
  • /BP: without an enclosure, to be mounted in a local cabinet. 190 x 180 x 130 mm, 1 Kg.
Input Power Options220 or 110 VAC (50 – 60 Hz) or 9 – 36 VDC (@ 5 Watts); may also be solar powered.
/4204-20 mA analog output proportional to ethanol concentration up to 100%, current source, not isolated.
/420/BGBar-Graph display (20 bars) of hydrocarbon thickness in addition to 4-20 mA analog output.
/CENZener Safety Barriers to allow installation of the sensor in hazardous areas.
/AUDAudio alarm option (available in weather-proof or explosion-proof enclosure)

Other Controllers – Refer to separate data sheets:

SLC-220: Digital Signal Processor for up to four ID-220 Series sensors support, with various output options, including relays, lights, 4-20 mA, LCD, Modbus communication in RS-232 and RS-485, and remote cellular connectivity.

Compare

Sensor models at a glance

Seven LEAKWISE ID-220 series sensors. Not sure which one fits? Use the Sensor Selection Tool →

Draft – compiled from the product pages and data sheets; to be checked against slide 29 of the sales-partners presentation
ModelWhat it measuresOil layer rangeWater level changeTypical useDetails
ID-221Oil sheen: detection + layer-thickness trend0.3 – 25 mm30 cm up to 45 mWet sumps, tanks, monitoring wells, oil/water separators, very deep sumps, sewersData sheet (PDF)
ID-223/500Oil sheen: detection + layer-thickness trend0.3 – 20 mm40 – 500 mmSumps (wet or dry), canals, retention ponds with small level changesData sheet (PDF)
ID-223/2000Oil sheen: detection + layer-thickness trend0.3 – 20 mm70 – 2,000 mm (up to 5,000 mm on request)Sumps (wet or dry), canals, retention ponds with large level changesData sheet (PDF)
ID-223/2500Oil sheen: detection + layer-thickness trend0.3 – 20 mm70 – 2,500 mm (up to 4,000 or 5,500 mm on request)Large level changes in small-area sumps, including dry sumpsData sheet (PDF)
ID-225/100Oil layer thickness (linear measurement)1 – 100 mm30 cm up to 45 mRemediation control, skim tanks, oil/water separators, wastewaterData sheet (PDF)
ID-225/200Oil layer thickness (linear measurement)1 – 200 mm33 cm up to 45 mRemediation control, skim tanks, oil/water separators, wastewaterData sheet (PDF)
ID-223ETEthanol concentration in water (also methanol)n/a – ethanol 10 – 100 % by volumeUp to 500 / 2,000 / 2,500 mm by sub-model (up to 5,000 / 5,500 mm on request)Ethanol storage tanks, separators and treatment plants, stormwater and wastewater at ethanol sitesData sheet (PDF)

Water level change = the range over which the floating sensor follows the surface. Minimum sump or well diameters differ by model – see the Sensor Selection Tool.