The PS-220 – Analog Controller

The PS-220 Analog LEAKWISE Controller serves as both a power supply and signal processor, interfacing with a single LEAKWISE ID-220 Series Sensor. It reports hydrocarbon spill/leak alerts, including hydrocarbon layer buildup and thickness, through local and remote outputs. With its proven reliability, the PS-220 offers a cost-effective solution for basic monitoring systems. Its versatile power options allow for either AC or DC line powering.

Applications:

The PS-220, paired with any LEAKWISE ID-220 Series Sensors, is typically used for oil spill/leak monitoring in various industrial settings. These include storage tank sumps, wastewater treatment discharge points, hydrocarbon pipeline pumping stations, hydroelectric and fossil fuel power plants, transformer substations, groundwater monitoring wells, and remediation sites.

Features:

  • Energy-efficient design with low power consumption
  • Integrated self-diagnostics for both controller and sensor
  • Streamlined calibration process
  • Dual adjustable alarm points for setting oil detection sensitivity

Principle of Operation:

The PS-220 provides a stabilized 12 VDC power supply to the sensor. It then filters and amplifies the current signal returned from the sensor. This processed signal is compared against two adjustable alarm set-points to determine the sensor’s status: Water, Oil, High-Oil, or Air, depending on the application.

The controller features two relay outputs with dry contacts for status reporting, and an additional fail-safe operated relay that alerts during sensor or power failures. A low-pass filter can be activated to prevent false alarms in turbulent water conditions. For enhanced monitoring, an optional 4-20 mA output reports oil layer thickness and trend, while an optional Bar-Graph provides visual representation of the oil layer thickness on the front panel, in addition to the standard status lights.

Download PDF

PS-220 Analog Controller Specifications:

The PS-220 Analog Controller is a signal processor and power supply for a single LEAKWISE ID-220 Series Sensor.

Key features include:

  • Wide operating temperature: -40 to 85°C (-40 to 185°F)
  • Sensor connection up to 1,200 m (3,937 ft.)
  • Dual alarm relays and one fail-safe fail indication relay
  • Multiple enclosure and power input options
  • Optional 4-20 mA output and Bar-Graph display
  • Applicability for installation in hazardous areas with Zener Safety Barriers and Explosion Proof or Flame Proof enclosure

Suitable for diverse industrial applications, the PS-220, together with a LEAKWISE sensor, offers reliable hydrocarbon leak detection and monitoring in both non-hazardous and hazardous environments.

Sensor SupportSingle LEAKWISE ID-220 Series Sensor.
EnclosureNEMA 4 (other enclosure options are available, see Enclosures and accessories).
TemperatureAmbient temperature range: -40 – 85 °C (-40 – 185 °F).
Cable length to SensorUp to 1,200 m (3,937 ft.) subject to hazardous area restrictions.
PS-220/RL/LITwo alarm relays with dry contacts and one fail relay contact: SPDT rated 4A (3A for fail contact) at 250 VAC or 30 VDC, normally open and normally closed, and four status indication lights: Water, Oil, Air / High Oil and Fail. Includes built-in diagnostics.
Wiring ConnectionsTerminal blocks: 14 AWG maximum for sensor and 4-20 mA output wires; 12 AWG maximum for power and relays wires.

Controller Certifications:

For hazardous areas:

North America – NEMA 7, Class I, Div 1, Groups B, C & D; NEMA 4

Europe ATEX & IECEx – II2(1)GD, Ex db [ia Ga] IIC T6 Gb IP66

Combined SystemApproved for operation in hazardous locations when Zener Safety Barriers are added
ManufacturingISO 9001:2015 Certified

Enclosure:

  • /N4 for NEMA 4X (IP65): 305 x 195 x 120 mm (12.0 x 7.7 x 4.7 in) 2 Kg (4.4 lb.);
  • /N7 for NEMA 7: 278 x 259 x 166 mm (11.0 x 10.2 x 6.5 in) 8.5 Kg (18.7 lb.);
  • /Exd for Ex d: 240 x 240 x 210mm (9.5 x 9.5 x 8.3 in), 11.3 Kg (24.9 lb.);
  • /BP: without an enclosure, to be mounted in a local cabinet. 190 x 180 x 130 mm, 1 Kg (2.2 lb.).

Options:

  • Input Power: 220 or 110 VAC (50 – 60 Hz) or 9 – 36 VDC (@ 5 Watts); may also be solar powered.
  • /420: 4-20 mA analog output proportional to hydrocarbon layer thickness (dependent on sensor model), current source.
  • /420/BG: Bar-Graph display (20 bars) of hydrocarbon thickness in addition to 4-20 mA analog output.
  • /CEN: Zener Safety Barriers to allow installation of the sensor in hazardous areas.
  • /AUD: Audio alarm option (available in weather-proof or explosion-proof enclosure).

Customize your monitoring solution